Insulation and pressure-proof test instrument
|
7100 Series 背面 |
便携式 |
MRO-7100 |
Type |
FunctionFunction |
YH-7110 |
AC Withstand Voltage Tester |
YH-7120 |
AC/DC Withstand Voltage Tester |
YH-7112 |
AC Withstand Voltage /Insulation Tester |
YH-7122 |
AC/DC Withstand Voltage/Insulation Tester |
YH-7130 |
AC/DC Withstand Voltage/Insulation Tester |
Product Features
Light, compact and portable AC pressure-proof testing 0-5KV DC pressure-proof testing 0-6KV Able to sense voltaic arc Digital keystroke input setting. Software modification Input voltage can increas automatically according to the setting
insulation resistance testing1-1000M∩(customization)
5 sets of testing conditions of automatic memory
Can be connected to YG7305 ground resistance test set for the purpose of automatic testing. Following tests can be achieved: W,1,W-1,1-W,AC&DC&IR Application
Electronics, electrical phase, transformer, electrical appliance, requested equipment for lighting products testing quality control, projects, EMI/EMC labs, requested equipment that needs to apply for national safety standards
Practical application The testing voltage for dielectric strength testers depends on the market that your product is going to enter into. You must comply with safety standard and regulations of the import control laws of the country. The safety standards specify the voltage and time for testing. The ideal condition is to ask your customers for relevant testing requirements. The normal voltage for testing is as follows: working voltage is from 42V to 1000V. The testing voltage is two time the working voltage with an additional of 1000V. For this testing voltage, it should take 1 minute.For example, for a product that works at 230V, its testing voltage is 1460V. Testing voltage should be increased if the time is deducted. YH7100 Series Specs List
Function/Type |
7122/7130(Non-standard) |
7120 |
7112 |
7110 |
Input features |
Single phase 47-63Hz,115/230V±15%(optional),3Afuse |
AC dielectric strength testing |
Rated output:5KV/12mA |
Output frequency |
60/50Hz(Optional) |
Output waveform |
distortion factor of sine wave﹤2%,crest factor 1.3-1.5 |
Upper limit |
range:0.1-12.00mA, distinguishability:0.01mA, accuracy:±(2% set value +2characters)*1 |
Lower limit |
range:0-12.00mA, distinguishability:0.01mA, accuracy:±(2% set value +2characters)*1 |
DC dielectric strength |
Rated output:6KV/5mA(YH-7130 can be extended to 10mA) |
|
﹤5%(在6KV/5mA,test under linear load) |
|
range:0.02-5.00, distinguishability:0.01mA accuracy:±(2% set value +2characters)*1 |
|
range:0.00-5.00mA, distinguishability:0.01mA accuracy:±(2% set value +2characters)*1 |
|
200ms |
|
distinguishabilit:10V, accuracy:±(2%set value+5V) |
|
range:0.1-999.9s, distinguishability:0.1s |
Test time |
range:0.0.2-999.9s, distinguishability:0.1s |
|
Sensitivity can be set:0-9(Note: Corresponding peak value:From 1 to 20mA;From 2 to 18mA;From 3 to 16mA; |
From 4 to 14mA; From 5 to 12mA; From 6 to 10mA; From 7 to 7.7mA; From 8 to 5.5mA; From 9 to 2.8mA |
|
range:AC0.10-12.00mA,DC0.02-5.00mA accuracy::±(2% set value +1 character) |
Ammeter |
range:AC0.10-12.00mA,DC0.02-5.00mA(YH7130 current range :0-10.00mA) |
accuracy r::±(2%set value +1 character) distinguishability:0.01mA |
Current range:AC0-11mA*2: Current range:DC0-4.5mA
Insulation resistance testing |
Suitable for 7112/7122/7130 |
Output voltage setting |
Range:DC0.00-1.00KV. distinguishability:0.01KV accuracy±(2%set value+2V) |
Voltmeter |
Range :DC0.10-1.00KV. distinguishability:0.01KV accuracy±(2%set value+1character) |
Megger |
Range :1-1000MΩ(4 digits, automatic shift)(Note:YH7130can be extended to 999MΩ) |
accuracy:±(3%set value+2 characters ),Voltage≥500V ±(7%set value+2characters),Voltage﹤500V |
Upper limit |
Range/Accuracy: the same with megger, Space:1MΩ |
Lower limit |
Range/Accuracy: the same with megger, Space:1MΩ |
Test time |
Range :0, 0.5-999.9s, distinguishability:0.1S(0= continuous testing) |
Common Specs |
7130 7122 7120 7112 7110 |
Remote control by programmed logic |
Input:(Test), (Reset) |
Output : (Pass), (Fail), (Test-in-Process) |
Test result |
Buzzer, LCD, Output by remote control |
Memory |
5sets of testing memory, 4 options of testing mode per set (W.1,W-1,1-W) |
Safe keyboard locking |
Safe keyboard locking, Prevent operators from making errors or changing programme by mistake |
LCD |
16×2 lattice, reverse characters |
Correction |
Correction is made by software. |
Usage environment |
Temperature 0-40℃ Relative temperature﹤80%RH |
Size |
89mm height×280mm width×370mm depth |
Weight |
About 9Kg |
|